The Trusted Source for Durable Cooling Fans

Data Rack Fan Intelligent 19" Cooling for Server & Network Cabinets

Reduce hot spots, extend equipment life, and maintain uptime with our ultra-reliable fan trays. From 1U basic to 4U intelligent with SNMP — designed for modern data centers.

Standard rack
0 "
1U-4U heights available
0
Cool Number
< 0 dBA
Rack Fans

Why a dedicated Data Rack Fan?

High Static Pressure

Designed to push air through dense server racks, not just general cabinet ventilation. Optimal for 1U servers with restricted intake.

Acoustic Comfort

Noise-optimized impellers and low-vibration motors keep sound below 40–55 dBA, meeting data center acoustic standards.

Remote Monitoring

Intelligent versions with tacho output, PWM control, and optional SNMP / Modbus for DCIM integration.

Redundancy Ready

N+1 fan configuration with hot-swappable modules ensures cooling continues even if a single fan fails.

EMC Protection

Metal housing with EMC shielding, optional finger guards and dust filters compliant with data center safety.

Wide Power Input

AC 110–240V or DC 24/48V, with dual power inputs for A/B feed in mission-critical racks.

Data Rack Fan families by U height

Standard 19″ width, depth from 250mm to 450mm. Tool-less mounting or slide rails.

data rack fan families by u height

1U Basic / Smart

1U · 4 fans (40mm)

2U Performance

2U · 6 or 8 fans (60mm)

3U High Flow

3U · 9 fans (80mm)

4U Redundant

4U · N+1 redundant

80-280mm

Size Range

110 V / 220 V

Voltage

–30°C ~ 80°C

Operation Temperature

50,000 hour

Service Life

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
110, 220
12/11
2500/2800
16.5/18.2
80×80×38
110, 220
13/12
2300/2500
47.6/56.1
92×92×25
110, 220
12/11
2350/2700
42.2/52.7
110×110×25
110, 220
12/11
2000/2200
41/45
120×120×25
110, 220
12/11
1800/2000
45/52.8
120×120×38
110, 220
19/18
2600/2900
77/82
120×120×38
110, 220
19/18
2500/2700
80/88
135×135×38
110, 220
20/18
2600/2800
86/95
150×150×51
110, 220
30/28
2700/3000
150/160
150×150×51
110, 220
32/30
2500/2600
175/185
172×150×38
220
30/29
2800/3300
184/225
172×150×51
110, 220
30/28
2700/3000
150/160
172×150×51
110, 220
32/30
2500/2600
175/185
172×172×52
220
40/39
2700/3200
233/281
172×162×55
110, 220
37/35
2800/3100
175/190
180×180×60
110, 220
42/40
2700/3000
260/290
202×202×60
110, 220
45/42
2600/2700
320/330
205×205×72
110, 220
60/80
2800/3200
630/680
220×60
110, 220
45/42
2600/2700
320/330
220×220×60
220
61/77
2550/2780
585/649
225×225×80
110, 220
55/65
2600/2800
500/545
254×89
110, 220
50/70
2550/2450
492/433
254×254×90
220
86/104
2660/3000
860/1003
280×280×80
110, 220
110/150
2550/2700
1015/1050

DC Fan Series

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
12, 24, 48
0.96 – 3.00
2500 – 4000
26.67 – 44.05
80×80×38
12, 24, 48
2.88 – 21.60
4000 – 8000
46.54 – 102.23
92×92×25
12, 24, 48
1.56 – 6.24
2500 – 4500
38.12 – 73.2
92×92×38
12, 24, 48
3.24 – 21.60
4000 – 7500
67.27 – 126.12
120×120×25
12, 24, 48
1.80 – 7.20
2000 – 3500
60.23 – 105.4
120×120×38
12, 24, 48
3.60 – 19.20
2500 – 4500
95.54 – 171.7
120×120×38
12, 24, 48
9.60 – 36.00
3500 – 5500
155.64 – 244.57
150×150×50
12, 24, 48
13.20 – 42.24
3000 – 4500
220.94 – 311.41
172×150×51
12, 24, 48
14.40 – 43.20
3000 – 4500
215.64 – 306.42
172×150×51
24, 48
156 – 245
6500 – 8000
490 – 605
200×200×60
12, 24, 48
25.80 – 65.76
2500 – 3500
380.17 – 532.24
205×205×72
12, 24, 48
57.6 – 120.0
2200 – 3300
531.3 – 798.3
220×60
12, 24, 48
24.0 – 57.6
2000 – 3000
396.7 – 581.0
225×225×80
12, 24, 48
57.6 – 120
2200 – 3300
533.5 – 806.0
254×89
12, 24, 48
19.2 – 96
2000 – 3000
628.3 – 970.1
280×280×80
12, 24, 48
57.6 – 168.0
2000 – 3000
790.1 – 1209.1

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

60×60×25
110~240
2, 4, 6
4000, 6000, 8000
14.1~28.7
70×70×25
110~240
2, 3, 4
2500, 3000, 3500
21.6~29.9
80×80×25
110~240
3, 4, 5
2400, 2800, 3200
26.3~35.2
80×80×38
110~240
3, 4, 6
2500, 3000, 3500
29.7~44.2
92×92×25
110~240
3, 5, 6
2000, 2500, 2800
30.1~42.1
92×92×38
110~240
4, 5, 7
2500, 3000, 3500
50.1~71.0
120×120×25
110~240
3, 4, 7
1800, 2200, 2600
55.6~79.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
110.7~170.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
79.3~125.0
150×150×51
110~240
16, 22, 35
2500, 3000, 3500
182.2~258.1
172×150×51
110~240
16, 22, 35
2500, 3000, 3500
177.4~253.9
172×51
110~240
16, 22, 35
2500, 3000, 3500
179.6~254.8
200×200×60
110~240
25, 45
2000, 2500
392.8~493.3
205×205×72
110~240
60, 95, 145
2500, 3000, 3600
602.7~851.7
220×60
110~240
25, 45
2000, 2500
396.6~490.8
225×225×80
110~240
60, 95, 145
2500, 3000, 3600
619.2~869.5
254×89
110/120~220/240
110, 115, 145
2000, 2500, 3200
628.3~981.6
280×280×80
110~240
45, 75, 145
2000, 2500, 3200
790.1~1225.7

Intelligent Data Rack Fan with DCIM integration

SNMP / Modbus TCP

Real-time RPM, temperature, and failure alerts directly into your DCIM or Nagios.

Embedded sensors

Built-in temperature/humidity sensors or external probe for dynamic fan speed.

PWM auto control

4-wire PWM fans adjust speed based on inlet temperature, saving energy.

Hot-swappable

Replace fans without powering down – critical for colocation and enterprise DC.

Where Data Rack Fans excel

Colocation cages

High density, remote monitoring

Network switches

Side-to-side cooling trays

Storage arrays

Even airflow across disks

Telecom shelters

Wide temp range, DC power

Edge data centers

Compact, low noise

Certifications of Rack Fans

FAQ of Rack Fans

What is a rack fan used for?

A rack fan is designed to improve airflow inside server racks and network cabinets. It removes hot air generated by equipment such as servers, switches, and power supplies, helping maintain stable operating temperatures and preventing overheating.

Rack fans are typically installed at the top or rear of the rack cabinet to exhaust hot air. Some fan trays are mounted in standard 1U or 2U rack positions to enhance internal airflow circulation.

Most rack fan trays are designed for standard 19-inch racks and come in 1U or 2U heights. They usually include two to six axial fans depending on the airflow requirements of the equipment.

Selecting the right rack fan depends on rack size, equipment heat load, and airflow requirements. Higher power servers or dense network equipment usually require fan trays with greater airflow capacity.

Yes. Rack fans should be checked regularly to ensure proper airflow and remove dust buildup. Periodic inspection and cleaning help maintain cooling efficiency and extend the service life of both fans and rack equipment.

Ready to Solve Your Cooling Challenge

linkwell cooling fan 1
Linkwell electric logo footer
Contact Us

Curious how LINKWELL’s cooling solutions can address your business challenges? Let’s connect and discuss your needs.