The Trusted Source for Durable Cooling Fans

Standard Fans Don’t Always Fit. We Engineer Custom Thermal Solutions That Do.

Custom airflow, pressure, voltage, and integration for electrical cabinets, telecom enclosures, automation equipment, battery systems, and industrial electronics.

custom thermal solutions

When Standard Cooling Isn’t Enough

Cabinet overheating

Internal temperatures rise above safe limits due to inadequate air exchange or high power density.

Restricted airflow path

Obstructions or narrow channels increase resistance and reduce cooling effectiveness significantly.

High static pressure requirement

Dense components or long ducting demand more pressure to maintain useful airflow rates.

Telecom enclosure heat buildup

Sealed, sun-exposed cabinets trap heat from continuous RF and power modules operation.

Battery enclosure thermal imbalance

Uneven cell temperatures accelerate aging and reduce charge/discharge efficiency across packs.

Unstable airflow in HVAC modules

Fluctuating flow causes inconsistent heat removal and intermittent hot spots in conditioned zones.

What We Customize — Engineered per Project

Electrical Matching

Mechanical Matching

Environmental Protection

Performance Tuning

Custom vs. Standard — a Real Difference

Comparison Factor Standard Fan Custom Thermal Solution
Voltage Fixed options Matched to your system
Size / Frame Standard frames Adapted to your space
IP Protection Limited Up to IP68
Connector / Cable As available Customized to your assembly
Speed Control Basic or none PWM / FG / Alarm
Bearing Type Standard Optimized for orientation/temp
Thermal Design Support
Airflow / Pressure Calculation

Fan Platforms: The Foundation of Your Custom Solution

Depending on the airflow path and system resistance, the final solution may use axial, centrifugal, EC, AC, or DC fan platforms.

We don’t sell an abstract service — we match the right fan technology to your thermal environment. Whether it’s high-pressure centrifugal for restricted enclosures or energy-efficient EC for variable loads, our engineering starts with physics, not a part number.

AC axial & centrifugal

Mains-powered industrial cabinets, HVAC

DC brushless

Telecom, battery, automation, low-voltage

EC Cooling Fans

Energy-efficient, PWM, intelligent control

Centrifugal Fans

Ducts, or confined internal pathways.

Engineering support — not just a fan supplier

cooling fan product integration and engineering support

Mechanical Matching

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
110, 220
12/11
2500/2800
16.5/18.2
80×80×38
110, 220
13/12
2300/2500
47.6/56.1
92×92×25
110, 220
12/11
2350/2700
42.2/52.7
110×110×25
110, 220
12/11
2000/2200
41/45
120×120×25
110, 220
12/11
1800/2000
45/52.8
120×120×38
110, 220
19/18
2600/2900
77/82
120×120×38
110, 220
19/18
2500/2700
80/88
135×135×38
110, 220
20/18
2600/2800
86/95
150×150×51
110, 220
30/28
2700/3000
150/160
150×150×51
110, 220
32/30
2500/2600
175/185
172×150×38
220
30/29
2800/3300
184/225
172×150×51
110, 220
30/28
2700/3000
150/160
172×150×51
110, 220
32/30
2500/2600
175/185
172×172×52
220
40/39
2700/3200
233/281
172×162×55
110, 220
37/35
2800/3100
175/190
180×180×60
110, 220
42/40
2700/3000
260/290
202×202×60
110, 220
45/42
2600/2700
320/330
205×205×72
110, 220
60/80
2800/3200
630/680
220×60
110, 220
45/42
2600/2700
320/330
220×220×60
220
61/77
2550/2780
585/649
225×225×80
110, 220
55/65
2600/2800
500/545
254×89
110, 220
50/70
2550/2450
492/433
254×254×90
220
86/104
2660/3000
860/1003
280×280×80
110, 220
110/150
2550/2700
1015/1050

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
12, 24, 48
0.96 – 3.00
2500 – 4000
26.67 – 44.05
80×80×38
12, 24, 48
2.88 – 21.60
4000 – 8000
46.54 – 102.23
92×92×25
12, 24, 48
1.56 – 6.24
2500 – 4500
38.12 – 73.2
92×92×38
12, 24, 48
3.24 – 21.60
4000 – 7500
67.27 – 126.12
120×120×25
12, 24, 48
1.80 – 7.20
2000 – 3500
60.23 – 105.4
120×120×38
12, 24, 48
3.60 – 19.20
2500 – 4500
95.54 – 171.7
120×120×38
12, 24, 48
9.60 – 36.00
3500 – 5500
155.64 – 244.57
150×150×50
12, 24, 48
13.20 – 42.24
3000 – 4500
220.94 – 311.41
172×150×51
12, 24, 48
14.40 – 43.20
3000 – 4500
215.64 – 306.42
172×150×51
24, 48
156 – 245
6500 – 8000
490 – 605
200×200×60
12, 24, 48
25.80 – 65.76
2500 – 3500
380.17 – 532.24
205×205×72
12, 24, 48
57.6 – 120.0
2200 – 3300
531.3 – 798.3
220×60
12, 24, 48
24.0 – 57.6
2000 – 3000
396.7 – 581.0
225×225×80
12, 24, 48
57.6 – 120
2200 – 3300
533.5 – 806.0
254×89
12, 24, 48
19.2 – 96
2000 – 3000
628.3 – 970.1
280×280×80
12, 24, 48
57.6 – 168.0
2000 – 3000
790.1 – 1209.1

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

60×60×25
110~240
2, 4, 6
4000, 6000, 8000
14.1~28.7
70×70×25
110~240
2, 3, 4
2500, 3000, 3500
21.6~29.9
80×80×25
110~240
3, 4, 5
2400, 2800, 3200
26.3~35.2
80×80×38
110~240
3, 4, 6
2500, 3000, 3500
29.7~44.2
92×92×25
110~240
3, 5, 6
2000, 2500, 2800
30.1~42.1
92×92×38
110~240
4, 5, 7
2500, 3000, 3500
50.1~71.0
120×120×25
110~240
3, 4, 7
1800, 2200, 2600
55.6~79.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
110.7~170.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
79.3~125.0
150×150×51
110~240
16, 22, 35
2500, 3000, 3500
182.2~258.1
172×150×51
110~240
16, 22, 35
2500, 3000, 3500
177.4~253.9
172×51
110~240
16, 22, 35
2500, 3000, 3500
179.6~254.8
200×200×60
110~240
25, 45
2000, 2500
392.8~493.3
205×205×72
110~240
60, 95, 145
2500, 3000, 3600
602.7~851.7
220×60
110~240
25, 45
2000, 2500
396.6~490.8
225×225×80
110~240
60, 95, 145
2500, 3000, 3600
619.2~869.5
254×89
110/120~220/240
110, 115, 145
2000, 2500, 3200
628.3~981.6
280×280×80
110~240
45, 75, 145
2000, 2500, 3200
790.1~1225.7

Real Engineering Case Studies

Application: PLC cabinet cooling upgrade
Thermal problem: Repeated temperature alarms; standard axial fan couldn’t push through dense component layout.
Solution chosen: Higher-static-pressure centrifugal blower with custom cable and mounting brackets.
Result: Improved internal airflow; hotspot eliminated around drive module.
Application: Outdoor telecom enclosure
Thermal problem: Heat buildup near power supply; standard fan airflow too diffuse.
Solution chosen: Custom voltage DC fan (24V) with focused airflow and IP55 protection.
Result: Stable thermal performance across -30°C to +65°C range.
Application: Battery enclosure thermal imbalance
Thermal problem: Temperature variation between upper and lower cells in stationary storage system.
Solution chosen: Dual centrifugal blower configuration with customized mounting plate.
Result: Uniform airflow distribution; passed UL validation tests.
Application: Industrial VFD panel
Thermal problem: Overheating under full load, fan filter clogging sensitivity.
Solution chosen: High-static AC fan with IP56-rated protection and ball bearing upgrade.
Result: Reduced maintenance cycles; 40% lower thermal alarm rate.

How We Work: Thermal Selection Process

1. Share thermal problem

2. Analyze airflow path & resistance

3. Match fan type (axial / centrifugal / EC / AC / DC)

4. Optimize pressure & airflow

5. Prototype validation

6. Mass production support

Quality Assurance – Custom Thermal Solutions

Why Oem Buyers Choose Fanacdc

Factory direct & engineering-led

Fast prototyping & stable lead times
Full customization (voltage, IP, connectors)
Industrial certifications: UL / CE / RoHS
Long service life (up to 60,000h)
Global shipment & OEM support

FAQ of Custom Thermal Solutions

What is a custom thermal solution?

A custom thermal solution means we design, select, or modify fan systems (voltage, airflow, pressure, mounting, and controls) to match your specific equipment’s heat load and spatial constraints — not just sell an off-shelf part.

When your system has restricted airflow paths, high static pressure requirements, unusual voltage, IP needs, or EMI/integration constraints that off-the-shelf models cannot satisfy.

Axial fans are suitable for low-resistance, open airflow. Centrifugal blowers excel when needing high static pressure, ducted systems, or compact cooling channels. Our engineering review decides based on your system resistance curve.

Yes — AC from 110V to 240V, DC from 12V/24V/48V, plus custom connectors, wire harness length, and labeling for OEM integration.

We deliver IP44 up to IP68 for outdoor, washdown, dusty, or marine environments.

That’s a core service: we calculate required CFM and Pa based on component heat dissipation and enclosure impedance, then recommend or customize accordingly.

Industrial automation, telecom infrastructure, battery ESS, HVAC/R, medical equipment, and power electronics — anywhere custom cooling matters.

Ready to Solve Your Cooling Challenge

oem cooling fan manufacturer · odm cooling fan manufacturer · china 12v dc cooling fan manufacturer · waterproof cooling fan · high quality cooling fan manufacturer

linkwell cooling fan 1
Linkwell electric logo footer
Contact Us

Curious how LINKWELL’s cooling solutions can address your business challenges? Let’s connect and discuss your needs.