The Trusted Source for Durable Cooling Fans

Reliable Cabinet Cooling Fan Supplier in China

Industrial Grade Heat Dissipation Solutions

High-airflow, low-noise, and long-lifespan axial fans designed for electrical enclosures, server racks, and control panels. UL/CE certified.

cabinet cooling fan supplier in china

80-280mm

Size Range

110 V / 220 V

Voltage

–30°C ~ 80°C

Operation Temperature

50,000 hour

Service Life

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
110, 220
12/11
2500/2800
16.5/18.2
80×80×38
110, 220
13/12
2300/2500
47.6/56.1
92×92×25
110, 220
12/11
2350/2700
42.2/52.7
110×110×25
110, 220
12/11
2000/2200
41/45
120×120×25
110, 220
12/11
1800/2000
45/52.8
120×120×38
110, 220
19/18
2600/2900
77/82
120×120×38
110, 220
19/18
2500/2700
80/88
135×135×38
110, 220
20/18
2600/2800
86/95
150×150×51
110, 220
30/28
2700/3000
150/160
150×150×51
110, 220
32/30
2500/2600
175/185
172×150×38
220
30/29
2800/3300
184/225
172×150×51
110, 220
30/28
2700/3000
150/160
172×150×51
110, 220
32/30
2500/2600
175/185
172×172×52
220
40/39
2700/3200
233/281
172×162×55
110, 220
37/35
2800/3100
175/190
180×180×60
110, 220
42/40
2700/3000
260/290
202×202×60
110, 220
45/42
2600/2700
320/330
205×205×72
110, 220
60/80
2800/3200
630/680
220×60
110, 220
45/42
2600/2700
320/330
220×220×60
220
61/77
2550/2780
585/649
225×225×80
110, 220
55/65
2600/2800
500/545
254×89
110, 220
50/70
2550/2450
492/433
254×254×90
220
86/104
2660/3000
860/1003
280×280×80
110, 220
110/150
2550/2700
1015/1050

DC Fan Series

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

80×80×25
12, 24, 48
0.96 – 3.00
2500 – 4000
26.67 – 44.05
80×80×38
12, 24, 48
2.88 – 21.60
4000 – 8000
46.54 – 102.23
92×92×25
12, 24, 48
1.56 – 6.24
2500 – 4500
38.12 – 73.2
92×92×38
12, 24, 48
3.24 – 21.60
4000 – 7500
67.27 – 126.12
120×120×25
12, 24, 48
1.80 – 7.20
2000 – 3500
60.23 – 105.4
120×120×38
12, 24, 48
3.60 – 19.20
2500 – 4500
95.54 – 171.7
120×120×38
12, 24, 48
9.60 – 36.00
3500 – 5500
155.64 – 244.57
150×150×50
12, 24, 48
13.20 – 42.24
3000 – 4500
220.94 – 311.41
172×150×51
12, 24, 48
14.40 – 43.20
3000 – 4500
215.64 – 306.42
172×150×51
24, 48
156 – 245
6500 – 8000
490 – 605
200×200×60
12, 24, 48
25.80 – 65.76
2500 – 3500
380.17 – 532.24
205×205×72
12, 24, 48
57.6 – 120.0
2200 – 3300
531.3 – 798.3
220×60
12, 24, 48
24.0 – 57.6
2000 – 3000
396.7 – 581.0
225×225×80
12, 24, 48
57.6 – 120
2200 – 3300
533.5 – 806.0
254×89
12, 24, 48
19.2 – 96
2000 – 3000
628.3 – 970.1
280×280×80
12, 24, 48
57.6 – 168.0
2000 – 3000
790.1 – 1209.1

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

60×60×25
110~240
2, 4, 6
4000, 6000, 8000
14.1~28.7
70×70×25
110~240
2, 3, 4
2500, 3000, 3500
21.6~29.9
80×80×25
110~240
3, 4, 5
2400, 2800, 3200
26.3~35.2
80×80×38
110~240
3, 4, 6
2500, 3000, 3500
29.7~44.2
92×92×25
110~240
3, 5, 6
2000, 2500, 2800
30.1~42.1
92×92×38
110~240
4, 5, 7
2500, 3000, 3500
50.1~71.0
120×120×25
110~240
3, 4, 7
1800, 2200, 2600
55.6~79.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
110.7~170.6
120×120×38
110~240
6, 8, 12, 18
2500, 3000, 3500, 4000
79.3~125.0
150×150×51
110~240
16, 22, 35
2500, 3000, 3500
182.2~258.1
172×150×51
110~240
16, 22, 35
2500, 3000, 3500
177.4~253.9
172×51
110~240
16, 22, 35
2500, 3000, 3500
179.6~254.8
200×200×60
110~240
25, 45
2000, 2500
392.8~493.3
205×205×72
110~240
60, 95, 145
2500, 3000, 3600
602.7~851.7
220×60
110~240
25, 45
2000, 2500
396.6~490.8
225×225×80
110~240
60, 95, 145
2500, 3000, 3600
619.2~869.5
254×89
110/120~220/240
110, 115, 145
2000, 2500, 3200
628.3~981.6
280×280×80
110~240
45, 75, 145
2000, 2500, 3200
790.1~1225.7

Without proper cabinet cooling, your equipment is at risk

Electrical cabinets trap heat from VFDs, PLCs, and power supplies. In a sealed enclosure, temperature can rise 15–25°C above ambient, leading to unexpected downtime, component failure, and safety hazards.

Temperature vs. Reliability (Arrhenius Study)

Cabinet Internal Temp Electronics Failure Rate Recommended Fan Action
25°C – 35°C Baseline Standard axial fan
35°C – 45°C 2x higher High-CFM fan
>45°C 5–10x higher Forced cooling + filter fan

Engineered for Industrial Enclosures

Ball Bearing Engineering

NMB/NSK genuine ball bearings ensure 50,000 – 70,000 hours continuous operation in high-temp cabinets.

Environmental Protection (IP55-IP68)

Coated PCB and sealed motor against dust, moisture, and oil mist. Ideal for factory floors and outdoor NEMA enclosures.

Flame Retardant Materials

UL94V-0 rated plastic blades or die-cast aluminum. Prevents fire risk and meets global electrical codes.

EMC Compliance

Low electromagnetic interference for sensitive electronics inside control panels – stable signal transmission.

How We Ensure Every Fan Is Reliable

1. IQC

100% motor winding & bearing test before assembly

2. IPQC

Balance & noise check at 4 assembly checkpoints

3. Burn-in

48h aging test on random batch samples

4. OQC

Final visual & anti-static packing, 3-year record retention

Iqc
Ipqc
Burn in
oqc

Cabinet Cooling Applications

Industrial Control Panels

PLC cabinets, automation lines – prevent unexpected shutdowns with continuous airflow.

Telecom Racks & Data

24/7 cooling for base stations, edge servers, high-density telecom enclosures.

Inverters & UPS

Photovoltaic inverters, energy storage systems – high CFM for high power density.

NEMA Enclosures

Outdoor & industrial cabinets requiring IP55, IP66, or IP68 rated fans.

Why Choose FanACDC as Your Cabinet Cooling Fan Supplier?

Certifications of Cabinet Cooling Fan Supplier in China

FAQ of Cabinet Cooling Fan Supplier in China

How do I calculate required CFM for my electrical cabinet?

Use this formula: CFM = (Heat load in Watts) / (1.08 × ΔT). Or simply send us your cabinet dimensions and internal heat sources – our engineers will recommend in 12h.

Exhaust pulls hot air out (negative pressure), intake pushes cool air in (positive pressure). For dusty environments, use intake with filter; for general cabinets, exhaust is common.

Yes, we supply fan + filter guard kits with IP54 rating for dust protection.

 12–24 months warranty. For defective fans, we provide replacement on next order or credit note. Video evidence is sufficient – no need to ship back small quantities.

Exhaust pulls hot air out (negative pressure), intake pushes cool air in (positive pressure). For dusty environments, use intake with filter; for general cabinets, exhaust is common.

Sample order from 1 piece. Bulk MOQ typically 100-500 pcs per model, and we accept mixed-model orders for distributors.

Ready to Solve Your Cooling Challenge

Contact our engineering and sales team for specifications, pricing, or a custom solution discussion.

linkwell cooling fan 1
Linkwell electric logo footer
Contact Us

Curious how LINKWELL’s cooling solutions can address your business challenges? Let’s connect and discuss your needs.