The Trusted Source for Durable Cooling Fans

Industrial Blower Fans Manufacturer

Our industrial blower fan range covers compact sizes from 133 to 355mm, delivering controlled airflow and dependable static pressure for enclosed industrial equipment and continuous operation environments.

Engineered for Superior Airflow

Compact Size & Installation Flexibility

Designed within a 133–355mm size range, these industrial blower fans fit compact equipment, control cabinets, and confined installations without sacrificing airflow performance or reliability.

Focused Airflow & Static Pressure

Small industrial blower fans prioritize controlled airflow combined with usable static pressure, making them suitable for ducted systems, enclosed housings, and resistance-heavy industrial environments.

Continuous Operation Capability

Built for long-duty cycles, these blower fans support continuous industrial operation with stable motor performance, consistent airflow output, and reduced thermal stress during extended runtime.

Industrial Application Compatibility

Commonly used in automation equipment, HVAC sub-systems, electronics cooling, and industrial machinery where space efficiency and dependable airflow control are required.

133-355 mm

Size Range

115-240 V

Voltage

159-1735 CFM

Air Volume

60,000 hour

Service Life

Industrial Blower Fans

Fan

Model

Size

(mm)

Voltage

(VAC)

Power

(W)

Speed

(RPM)

Airflow

(CFM)

355×95
110~380
65-250
910-1600
649~1247
355×60
110~380
68-145
940-1600
649~1247
316×102
110~380
68-170
940-1600
826~1390
280×51
110~220
110-305
1400-2700
649~1245
250×56
110~220
70-208
1400-2800
478~897
225×63
110~380
65-180
1480-2950
419~791
220×44
110~380
48-125
1400-2900
273~578
190×45
110~380
27-74
1400-2700
182~366
175×42
110~380
56-64
2500-2900
159~177
133×41
110~380
34-39
2550-2700
159~177

Certifications of Industrial Blower Fans

Industrial Blower Fans Components

centrifugal fan impeller

Impeller

The impeller is precisely balanced to generate directional airflow and static pressure, directly affecting efficiency, noise levels, and overall blower fan performance.

housing casing volute

Housing/Casing/Volute

The housing or volute guides airflow efficiently from the impeller, converting velocity into pressure while minimizing turbulence, leakage, and operational noise.

centrifugal fan motor

Drive System

The drive system, including motor and bearings, ensures stable rotation, consistent torque output, and long service life under continuous industrial operating conditions.

Company Profile

With over 20 years of engineering expertise, LINKWELL is a trusted manufacturer of industrial blower fans, delivering reliable airflow solutions for demanding industrial applications.

About LINKWELL

LINKWELL designs and manufactures high-performance cooling solutions for industries including industrial automation, power electronics, renewable energy, and telecommunications.

Our product range features Industrial Blower Fans, alongside centrifugal, DC, and EC fans, serving global markets. As an industry innovator, we continuously advance cutting-edge technologies to meet evolving client demands.

Driven by reliability and customer focus, LINKWELL provides professional OEM, ODM, and OBM services to deliver customized airflow solutions.

industrial blower fans factory
industrial blower fans manufacture
oem industrial blower fans
industrial blower fans factory (1)

Customization Services

We offer comprehensive OEM, ODM, and OBM services to deliver solutions tailored to your specific requirements

Fan Size & Structural Design Customization

We customize blower fan dimensions, mounting holes, inlet/outlet orientation, and casing structure to match equipment layouts, installation constraints, and airflow paths.

Airflow & Pressure Performance Tuning

Airflow volume and static pressure can be adjusted through impeller design, blade angle, and motor matching to meet specific thermal and resistance requirements.

Voltage, Frequency & Electrical Configuration

We support multiple voltages and frequencies, including regional power standards, ensuring electrical compatibility, operational stability, and compliance with global industrial systems.

Materials, Noise & Durability Options

Material selection, bearing type, insulation class, and noise optimization can be customized to improve durability, reduce vibration, and extend service life.

FAQ of Industrial Blower Fans

What is an industrial blower fan used for?

Industrial blower fans are used to move air through ducts or enclosed systems, providing controlled airflow and static pressure for cooling, ventilation, or process support in industrial equipment.

 

Blower fans generate higher static pressure and controlled airflow direction, making them more suitable for ducted or enclosed systems compared to axial fans.

 

Yes. When properly designed, small industrial blower fans support continuous operation with stable airflow, reliable motor performance, and controlled thermal characteristics.

 

 

Small industrial blower fans typically range from 133mm to 355mm, balancing compact installation requirements with sufficient airflow and pressure output.

 

 

 

Industrial blower fans can be customized in size, airflow performance, voltage, mounting structure, and materials to match specific equipment and application requirements.

 

 

 

 

Impeller design, housing structure, motor power, system resistance, and installation environment all directly influence airflow volume and static pressure.

 

 

 

 

 

Ready to Solve Your Cooling Challenge

linkwell cooling fan 1
Linkwell electric logo footer
Contact Us

Curious how LINKWELL’s cooling solutions can address your business challenges? Let’s connect and discuss your needs.